mirror of
https://github.com/torvalds/linux.git
synced 2024-11-18 10:01:43 +00:00
Merge branch 'pci/virtualization'
- Fix problem with caching VF config space size (Alex Williamson) * pci/virtualization: PCI/IOV: Assume SR-IOV VFs support extended config space. Revert "PCI/IOV: Use VF0 cached config space size for other VFs"
This commit is contained in:
commit
55ab3ecb81
@ -132,8 +132,6 @@ static void pci_read_vf_config_common(struct pci_dev *virtfn)
|
||||
&physfn->sriov->subsystem_vendor);
|
||||
pci_read_config_word(virtfn, PCI_SUBSYSTEM_ID,
|
||||
&physfn->sriov->subsystem_device);
|
||||
|
||||
physfn->sriov->cfg_size = pci_cfg_space_size(virtfn);
|
||||
}
|
||||
|
||||
int pci_iov_add_virtfn(struct pci_dev *dev, int id)
|
||||
|
@ -293,7 +293,6 @@ struct pci_sriov {
|
||||
u16 driver_max_VFs; /* Max num VFs driver supports */
|
||||
struct pci_dev *dev; /* Lowest numbered PF */
|
||||
struct pci_dev *self; /* This PF */
|
||||
u32 cfg_size; /* VF config space size */
|
||||
u32 class; /* VF device */
|
||||
u8 hdr_type; /* VF header type */
|
||||
u16 subsystem_vendor; /* VF subsystem vendor */
|
||||
|
@ -1555,17 +1555,6 @@ static int pci_cfg_space_size_ext(struct pci_dev *dev)
|
||||
return PCI_CFG_SPACE_EXP_SIZE;
|
||||
}
|
||||
|
||||
#ifdef CONFIG_PCI_IOV
|
||||
static bool is_vf0(struct pci_dev *dev)
|
||||
{
|
||||
if (pci_iov_virtfn_devfn(dev->physfn, 0) == dev->devfn &&
|
||||
pci_iov_virtfn_bus(dev->physfn, 0) == dev->bus->number)
|
||||
return true;
|
||||
|
||||
return false;
|
||||
}
|
||||
#endif
|
||||
|
||||
int pci_cfg_space_size(struct pci_dev *dev)
|
||||
{
|
||||
int pos;
|
||||
@ -1573,9 +1562,18 @@ int pci_cfg_space_size(struct pci_dev *dev)
|
||||
u16 class;
|
||||
|
||||
#ifdef CONFIG_PCI_IOV
|
||||
/* Read cached value for all VFs except for VF0 */
|
||||
if (dev->is_virtfn && !is_vf0(dev))
|
||||
return dev->physfn->sriov->cfg_size;
|
||||
/*
|
||||
* Per the SR-IOV specification (rev 1.1, sec 3.5), VFs are required to
|
||||
* implement a PCIe capability and therefore must implement extended
|
||||
* config space. We can skip the NO_EXTCFG test below and the
|
||||
* reachability/aliasing test in pci_cfg_space_size_ext() by virtue of
|
||||
* the fact that the SR-IOV capability on the PF resides in extended
|
||||
* config space and must be accessible and non-aliased to have enabled
|
||||
* support for this VF. This is a micro performance optimization for
|
||||
* systems supporting many VFs.
|
||||
*/
|
||||
if (dev->is_virtfn)
|
||||
return PCI_CFG_SPACE_EXP_SIZE;
|
||||
#endif
|
||||
|
||||
if (dev->bus->bus_flags & PCI_BUS_FLAGS_NO_EXTCFG)
|
||||
|
Loading…
Reference in New Issue
Block a user