hwmon: (tmp421) report /PVLD condition as fault
For both local and remote sensors all the supported ICs can report an
"undervoltage lockout" condition which means the conversion wasn't
properly performed due to insufficient power supply voltage and so the
measurement results can't be trusted.
Fixes: 9410700b88
("hwmon: Add driver for Texas Instruments TMP421/422/423 sensor chips")
Signed-off-by: Paul Fertser <fercerpav@gmail.com>
Link: https://lore.kernel.org/r/20210924093011.26083-2-fercerpav@gmail.com
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
This commit is contained in:
parent
2938b2978a
commit
540effa7f2
@ -179,10 +179,10 @@ static int tmp421_read(struct device *dev, enum hwmon_sensor_types type,
|
||||
return 0;
|
||||
case hwmon_temp_fault:
|
||||
/*
|
||||
* The OPEN bit signals a fault. This is bit 0 of the temperature
|
||||
* register (low byte).
|
||||
* Any of OPEN or /PVLD bits indicate a hardware mulfunction
|
||||
* and the conversion result may be incorrect
|
||||
*/
|
||||
*val = tmp421->temp[channel] & 0x01;
|
||||
*val = !!(tmp421->temp[channel] & 0x03);
|
||||
return 0;
|
||||