mirror of
https://github.com/torvalds/linux.git
synced 2024-11-18 01:51:53 +00:00
nvmet-fc: bring Disconnect into compliance with FC-NVME spec
The FC-NVME spec, when finally approved, modified the disconnect LS such that the only scope available is the association. Rework the Disconnect LS processing to be in accordance with the change. Signed-off-by: Nigel Kirkland <nigel.kirkland@broadcom.com> Signed-off-by: James Smart <jsmart2021@gmail.com> Reviewed-by: Ewan D. Milne <emilne@redhat.com> Signed-off-by: Christoph Hellwig <hch@lst.de> Signed-off-by: Jens Axboe <axboe@kernel.dk>
This commit is contained in:
parent
0191e7405b
commit
404ec31df4
@ -1502,10 +1502,8 @@ nvmet_fc_ls_disconnect(struct nvmet_fc_tgtport *tgtport,
|
|||||||
(struct fcnvme_ls_disconnect_rqst *)iod->rqstbuf;
|
(struct fcnvme_ls_disconnect_rqst *)iod->rqstbuf;
|
||||||
struct fcnvme_ls_disconnect_acc *acc =
|
struct fcnvme_ls_disconnect_acc *acc =
|
||||||
(struct fcnvme_ls_disconnect_acc *)iod->rspbuf;
|
(struct fcnvme_ls_disconnect_acc *)iod->rspbuf;
|
||||||
struct nvmet_fc_tgt_queue *queue = NULL;
|
|
||||||
struct nvmet_fc_tgt_assoc *assoc;
|
struct nvmet_fc_tgt_assoc *assoc;
|
||||||
int ret = 0;
|
int ret = 0;
|
||||||
bool del_assoc = false;
|
|
||||||
|
|
||||||
memset(acc, 0, sizeof(*acc));
|
memset(acc, 0, sizeof(*acc));
|
||||||
|
|
||||||
@ -1536,18 +1534,7 @@ nvmet_fc_ls_disconnect(struct nvmet_fc_tgtport *tgtport,
|
|||||||
assoc = nvmet_fc_find_target_assoc(tgtport,
|
assoc = nvmet_fc_find_target_assoc(tgtport,
|
||||||
be64_to_cpu(rqst->associd.association_id));
|
be64_to_cpu(rqst->associd.association_id));
|
||||||
iod->assoc = assoc;
|
iod->assoc = assoc;
|
||||||
if (assoc) {
|
if (!assoc)
|
||||||
if (rqst->discon_cmd.scope ==
|
|
||||||
FCNVME_DISCONN_CONNECTION) {
|
|
||||||
queue = nvmet_fc_find_target_queue(tgtport,
|
|
||||||
be64_to_cpu(
|
|
||||||
rqst->discon_cmd.id));
|
|
||||||
if (!queue) {
|
|
||||||
nvmet_fc_tgt_a_put(assoc);
|
|
||||||
ret = VERR_NO_CONN;
|
|
||||||
}
|
|
||||||
}
|
|
||||||
} else
|
|
||||||
ret = VERR_NO_ASSOC;
|
ret = VERR_NO_ASSOC;
|
||||||
}
|
}
|
||||||
|
|
||||||
@ -1575,26 +1562,10 @@ nvmet_fc_ls_disconnect(struct nvmet_fc_tgtport *tgtport,
|
|||||||
sizeof(struct fcnvme_ls_disconnect_acc)),
|
sizeof(struct fcnvme_ls_disconnect_acc)),
|
||||||
FCNVME_LS_DISCONNECT);
|
FCNVME_LS_DISCONNECT);
|
||||||
|
|
||||||
|
|
||||||
/* are we to delete a Connection ID (queue) */
|
|
||||||
if (queue) {
|
|
||||||
int qid = queue->qid;
|
|
||||||
|
|
||||||
nvmet_fc_delete_target_queue(queue);
|
|
||||||
|
|
||||||
/* release the get taken by find_target_queue */
|
|
||||||
nvmet_fc_tgt_q_put(queue);
|
|
||||||
|
|
||||||
/* tear association down if io queue terminated */
|
|
||||||
if (!qid)
|
|
||||||
del_assoc = true;
|
|
||||||
}
|
|
||||||
|
|
||||||
/* release get taken in nvmet_fc_find_target_assoc */
|
/* release get taken in nvmet_fc_find_target_assoc */
|
||||||
nvmet_fc_tgt_a_put(iod->assoc);
|
nvmet_fc_tgt_a_put(iod->assoc);
|
||||||
|
|
||||||
if (del_assoc)
|
nvmet_fc_delete_target_assoc(iod->assoc);
|
||||||
nvmet_fc_delete_target_assoc(iod->assoc);
|
|
||||||
}
|
}
|
||||||
|
|
||||||
|
|
||||||
|
Loading…
Reference in New Issue
Block a user