DMA: fix AMBA PL08x compilation issue with 64bit DMA address type

When dma_addr_t is 64 bits long, compilation of the AMBA PL08x DMA
driver breaks due to a missing 64bit%8bit modulo operation.
Looking more closely the divisor in these operations can only be
1, 2 or 4, so the full featured '%' modulo operation is overkill and
can be replaced with simple bit masking.

Change from v1:
Replace open-coded function with existing IS_ALIGNED macro and use a
macro around that to avoid a line becoming too long.

Signed-off-by: Andre Przywara <andre.przywara@linaro.org>
Acked-by: Vinod Koul <vinod.koul@intel.com>
Signed-off-by: Rob Herring <rob.herring@calxeda.com>
This commit is contained in:
Andre Przywara 2013-08-19 12:19:28 +02:00 committed by Rob Herring
parent 2c63494625
commit 1c38b28980

View File

@ -133,6 +133,8 @@ struct pl08x_bus_data {
u8 buswidth;
};
#define IS_BUS_ALIGNED(bus) IS_ALIGNED((bus)->addr, (bus)->buswidth)
/**
* struct pl08x_phy_chan - holder for the physical channels
* @id: physical index to this channel
@ -886,8 +888,8 @@ static int pl08x_fill_llis_for_desc(struct pl08x_driver_data *pl08x,
return 0;
}
if ((bd.srcbus.addr % bd.srcbus.buswidth) ||
(bd.dstbus.addr % bd.dstbus.buswidth)) {
if (!IS_BUS_ALIGNED(&bd.srcbus) ||
!IS_BUS_ALIGNED(&bd.dstbus)) {
dev_err(&pl08x->adev->dev,
"%s src & dst address must be aligned to src"
" & dst width if peripheral is flow controller",
@ -908,9 +910,9 @@ static int pl08x_fill_llis_for_desc(struct pl08x_driver_data *pl08x,
*/
if (bd.remainder < mbus->buswidth)
early_bytes = bd.remainder;
else if ((mbus->addr) % (mbus->buswidth)) {
early_bytes = mbus->buswidth - (mbus->addr) %
(mbus->buswidth);
else if (!IS_BUS_ALIGNED(mbus)) {
early_bytes = mbus->buswidth -
(mbus->addr & (mbus->buswidth - 1));
if ((bd.remainder - early_bytes) < mbus->buswidth)
early_bytes = bd.remainder;
}
@ -928,7 +930,7 @@ static int pl08x_fill_llis_for_desc(struct pl08x_driver_data *pl08x,
* Master now aligned
* - if slave is not then we must set its width down
*/
if (sbus->addr % sbus->buswidth) {
if (!IS_BUS_ALIGNED(sbus)) {
dev_dbg(&pl08x->adev->dev,
"%s set down bus width to one byte\n",
__func__);