hwmon: (pmbus) Documentation updates

Fix spelling, correct label name error, and add missing attribute to PMBus
driver documentation.

Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
Reviewed-by: Tom Grennan <tom.grennan@ericsson.com>
This commit is contained in:
Guenter Roeck 2011-04-18 09:48:58 -07:00
parent c1a76b4741
commit 180b3d889c

View File

@ -175,11 +175,13 @@ currX_crit Critical maximum current.
From IIN_OC_FAULT_LIMIT or IOUT_OC_FAULT_LIMIT register.
currX_alarm Current high alarm.
From IIN_OC_WARNING or IOUT_OC_WARNING status.
currX_max_alarm Current high alarm.
From IIN_OC_WARN_LIMIT or IOUT_OC_WARN_LIMIT status.
currX_lcrit_alarm Output current critical low alarm.
From IOUT_UC_FAULT status.
currX_crit_alarm Current critical high alarm.
From IIN_OC_FAULT or IOUT_OC_FAULT status.
currX_label "iin" or "vinY"
currX_label "iin" or "ioutY"
powerX_input Measured power. From READ_PIN or READ_POUT register.
powerX_cap Output power cap. From POUT_MAX register.
@ -193,13 +195,13 @@ powerX_crit_alarm Output power critical high alarm.
From POUT_OP_FAULT status.
powerX_label "pin" or "poutY"
tempX_input Measured tempererature.
tempX_input Measured temperature.
From READ_TEMPERATURE_X register.
tempX_min Mimimum tempererature. From UT_WARN_LIMIT register.
tempX_max Maximum tempererature. From OT_WARN_LIMIT register.
tempX_lcrit Critical low tempererature.
tempX_min Mimimum temperature. From UT_WARN_LIMIT register.
tempX_max Maximum temperature. From OT_WARN_LIMIT register.
tempX_lcrit Critical low temperature.
From UT_FAULT_LIMIT register.
tempX_crit Critical high tempererature.
tempX_crit Critical high temperature.
From OT_FAULT_LIMIT register.
tempX_min_alarm Chip temperature low alarm. Set by comparing
READ_TEMPERATURE_X with UT_WARN_LIMIT if