charger-manager: Fix bug related to checking fully charged state of battery

This patch fix bug related to checking fully charged state of battery when
charger-manager call is_full_charged() function. After reading property of
charger/fuel-gauge through power_supply API, val.intval is more than 1.
So, is_full_charged() function always return true. If true, battery means
fully charged state.

Signed-off-by: Chanwoo Choi <cw00.choi@samsung.com>
Signed-off-by: Myungjoo Ham <myungjoo.ham@samsung.com>
Signed-off-by: Kyungmin Park <kyungmin.park@samsung.com>
Signed-off-by: Anton Vorontsov <anton.vorontsov@linaro.org>
This commit is contained in:
Chanwoo Choi 2012-11-22 16:53:46 +09:00 committed by Anton Vorontsov
parent 7605c0b0d3
commit 0fa11dbc23

View File

@ -239,44 +239,37 @@ static bool is_full_charged(struct charger_manager *cm)
int uV;
/* If there is no battery, it cannot be charged */
if (!is_batt_present(cm)) {
val.intval = 0;
goto out;
}
if (!is_batt_present(cm))
return false;
if (cm->fuel_gauge && desc->fullbatt_full_capacity > 0) {
val.intval = 0;
/* Not full if capacity of fuel gauge isn't full */
ret = cm->fuel_gauge->get_property(cm->fuel_gauge,
POWER_SUPPLY_PROP_CHARGE_FULL, &val);
if (!ret && val.intval > desc->fullbatt_full_capacity) {
val.intval = 1;
goto out;
}
if (!ret && val.intval > desc->fullbatt_full_capacity)
return true;
}
/* Full, if it's over the fullbatt voltage */
if (desc->fullbatt_uV > 0) {
ret = get_batt_uV(cm, &uV);
if (!ret && uV >= desc->fullbatt_uV) {
val.intval = 1;
goto out;
}
if (!ret && uV >= desc->fullbatt_uV)
return true;
}
/* Full, if the capacity is more than fullbatt_soc */
if (cm->fuel_gauge && desc->fullbatt_soc > 0) {
val.intval = 0;
ret = cm->fuel_gauge->get_property(cm->fuel_gauge,
POWER_SUPPLY_PROP_CAPACITY, &val);
if (!ret && val.intval >= desc->fullbatt_soc) {
val.intval = 1;
goto out;
}
if (!ret && val.intval >= desc->fullbatt_soc)
return true;
}
val.intval = 0;
out:
return val.intval ? true : false;