mirror of
https://github.com/torvalds/linux.git
synced 2024-11-18 10:01:43 +00:00
arm: dts: add omap4 CPU thermal data
This patch changes a dtsi file to contain the thermal data for MPU domain on OMAP4 and later SoCs. This data will enable the passive cooling with CPUfreq cooling device at 100C and the system will do a thermal shutdown at 125C. This thermal data can be reused across TI SoC devices. Cc: "Benoît Cousson" <bcousson@baylibre.com> Cc: Tony Lindgren <tony@atomide.com> Cc: Rob Herring <rob.herring@calxeda.com> Cc: Pawel Moll <pawel.moll@arm.com> Cc: Mark Rutland <mark.rutland@arm.com> Cc: Stephen Warren <swarren@wwwdotorg.org> Cc: Ian Campbell <ian.campbell@citrix.com> Cc: Russell King <linux@arm.linux.org.uk> Cc: linux-omap@vger.kernel.org Cc: devicetree@vger.kernel.org Cc: linux-arm-kernel@lists.infradead.org Cc: linux-kernel@vger.kernel.org Signed-off-by: Eduardo Valentin <eduardo.valentin@ti.com>
This commit is contained in:
parent
26d9cc65fa
commit
0bbf6c54d1
41
arch/arm/boot/dts/omap4-cpu-thermal.dtsi
Normal file
41
arch/arm/boot/dts/omap4-cpu-thermal.dtsi
Normal file
@ -0,0 +1,41 @@
|
||||
/*
|
||||
* Device Tree Source for OMAP4/5 SoC CPU thermal
|
||||
*
|
||||
* Copyright (C) 2013 Texas Instruments Incorporated - http://www.ti.com/
|
||||
* Contact: Eduardo Valentin <eduardo.valentin@ti.com>
|
||||
*
|
||||
* This file is licensed under the terms of the GNU General Public License
|
||||
* version 2. This program is licensed "as is" without any warranty of any
|
||||
* kind, whether express or implied.
|
||||
*/
|
||||
|
||||
#include <dt-bindings/thermal/thermal.h>
|
||||
|
||||
cpu_thermal: cpu_thermal {
|
||||
polling-delay-passive = <250>; /* milliseconds */
|
||||
polling-delay = <1000>; /* milliseconds */
|
||||
|
||||
/* sensor ID */
|
||||
thermal-sensors = <&bandgap 0>;
|
||||
|
||||
trips {
|
||||
cpu_alert0: cpu_alert {
|
||||
temperature = <100000>; /* millicelsius */
|
||||
hysteresis = <2000>; /* millicelsius */
|
||||
type = "passive";
|
||||
};
|
||||
cpu_crit: cpu_crit {
|
||||
temperature = <125000>; /* millicelsius */
|
||||
hysteresis = <2000>; /* millicelsius */
|
||||
type = "critical";
|
||||
};
|
||||
};
|
||||
|
||||
cooling-maps {
|
||||
map0 {
|
||||
trip = <&cpu_alert0>;
|
||||
cooling-device =
|
||||
<&cpu0 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>;
|
||||
};
|
||||
};
|
||||
};
|
Loading…
Reference in New Issue
Block a user