mirror of
https://github.com/torvalds/linux.git
synced 2024-12-28 22:02:28 +00:00
thermal/intel/intel_soc_dts_iosf: Fix reporting wrong temperatures
Since commit955fb8719e
("thermal/intel/intel_soc_dts_iosf: Use Intel TCC library") intel_soc_dts_iosf is reporting the wrong temperature. The driver expects tj_max to be in milli-degrees-celcius but after the switch to the TCC library this is now in degrees celcius so instead of e.g. 90000 it is set to 90 causing a temperature 45 degrees below tj_max to be reported as -44910 milli-degrees instead of as 45000 milli-degrees. Fix this by adding back the lost factor of 1000. Fixes:955fb8719e
("thermal/intel/intel_soc_dts_iosf: Use Intel TCC library") Reported-by: Bernhard Krug <b.krug@elektronenpumpe.de> Signed-off-by: Hans de Goede <hdegoede@redhat.com> Acked-by: Zhang Rui <rui.zhang@intel.com> Cc: 6.3+ <stable@vger.kernel.org> # 6.3+ Signed-off-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com>
This commit is contained in:
parent
858fd168a9
commit
0bb619f922
@ -398,7 +398,7 @@ struct intel_soc_dts_sensors *intel_soc_dts_iosf_init(
|
||||
spin_lock_init(&sensors->intr_notify_lock);
|
||||
mutex_init(&sensors->dts_update_lock);
|
||||
sensors->intr_type = intr_type;
|
||||
sensors->tj_max = tj_max;
|
||||
sensors->tj_max = tj_max * 1000;
|
||||
if (intr_type == INTEL_SOC_DTS_INTERRUPT_NONE)
|
||||
notification = false;
|
||||
else
|
||||
|
Loading…
Reference in New Issue
Block a user