scsi: lpfc: Fix issuing init_vpi mbox on SLI-3 card
The driver is inadvertently trying to issue an INIT_VPI mailbox command on an SLI-3 driver. The command is specific to SLI-4. When the call is made to send the command, if on an SLI-3 adapter, an array pointer is NULL and the driver will oops. Fix by restricting the command to SLI-4 adapters only. Signed-off-by: Dick Kennedy <dick.kennedy@broadcom.com> Signed-off-by: James Smart <jsmart2021@gmail.com> Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
This commit is contained in:
parent
26d824ca45
commit
08180db254
@ -527,9 +527,11 @@ disable_vport(struct fc_vport *fc_vport)
|
||||
* scsi_host_put() to release the vport.
|
||||
*/
|
||||
lpfc_mbx_unreg_vpi(vport);
|
||||
spin_lock_irq(shost->host_lock);
|
||||
vport->fc_flag |= FC_VPORT_NEEDS_INIT_VPI;
|
||||
spin_unlock_irq(shost->host_lock);
|
||||
if (phba->sli_rev == LPFC_SLI_REV4) {
|
||||
spin_lock_irq(shost->host_lock);
|
||||
vport->fc_flag |= FC_VPORT_NEEDS_INIT_VPI;
|
||||
spin_unlock_irq(shost->host_lock);
|
||||
}
|
||||
|
||||
lpfc_vport_set_state(vport, FC_VPORT_DISABLED);
|
||||
lpfc_printf_vlog(vport, KERN_ERR, LOG_VPORT,
|
||||
|
Loading…