mirror of
https://github.com/torvalds/linux.git
synced 2024-11-13 15:41:39 +00:00
drm/amd/display: Report non-DP display as disconnected without EDID
[Why] Some boards seem to have a problem where HPD is high on HDMI even though no display is connected. We don't want to report these as connected. DP spec still requires us to report DP displays as connected when HPD is high but we can't read the EDID in order to go to fail-safe mode. [How] If connector_signal is not DP abort detection if we can't retrieve the EDID. v2: Add Bugzilla and stable Bugzilla: https://bugs.freedesktop.org/107390 Bugzilla: https://bugs.freedesktop.org/106846 Cc: stable@vger.kernel.org Signed-off-by: Harry Wentland <harry.wentland@amd.com> Acked-by: Alex Deucher <alexander.deucher@amd.com> Reviewed-by: Nicholas Kazlauskas <nicholas.kazlauskas@amd.com> Signed-off-by: Alex Deucher <alexander.deucher@amd.com>
This commit is contained in:
parent
df36b2fb83
commit
01dc285d5c
@ -744,6 +744,17 @@ bool dc_link_detect(struct dc_link *link, enum dc_detect_reason reason)
|
||||
break;
|
||||
case EDID_NO_RESPONSE:
|
||||
DC_LOG_ERROR("No EDID read.\n");
|
||||
|
||||
/*
|
||||
* Abort detection for non-DP connectors if we have
|
||||
* no EDID
|
||||
*
|
||||
* DP needs to report as connected if HDP is high
|
||||
* even if we have no EDID in order to go to
|
||||
* fail-safe mode
|
||||
*/
|
||||
if (!dc_is_dp_signal(link->connector_signal))
|
||||
return false;
|
||||
default:
|
||||
break;
|
||||
}
|
||||
|
Loading…
Reference in New Issue
Block a user